Sensor fault and coping methods

1, power supply capacity caused by lack of wave electronic ruler -- The power supply capacity of forstability

2, FM interference and electrostatic interference caused by electronic scale digital display beating -power lines and signal line equipment to separate line slot

3, display data beating regularly, or there is no display data -- check wire breakage or short circuit

4, the installation will cause a bad beating - mounted display digital linear displacement sensor forneutral good, but the parallelism allows error - 0.5mm, angle is allowed error of plus or minus 12 degrees.